- 6 -
STEP 2:
Mounting the IMC-101G on the wall requires 4
screws. Use the IMC-101G, with wall mount plates
attached, as a guide to mark the correct locations of the
4 screws. The heads of the screws should be less than
6.0 mm in diameter, and the shafts should be less than
3.5 mm in diameter, as shown in the figure at the right.
6.0 mm
3.5 mm
NOTE
Test the screw head and shank size by inserting the screw into one of the
keyhole shaped apertures of the Wall Mounting Plates, before it is screwed into
the wall.
Do not screw the screws in all the way—leave a space of about 2 mm to allow
room for sliding the wall mount panel between the wall and the screws.
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the
large parts of the keyhole-shaped apertures, and then slide the IMC-101G
downwards, as indicated below. Tighten the four screws for added stability.
G1
G2
G2
G1
1
0
0
0M
G
G2
IMC-101G
G1
1000M
G2
G1
G1
G2
G2
G1
1
0
0
0M
G
G2
IMC-101G
G1
1000M
G2
G1
II 3G
ATEX Information
1. Certification number DEMKO 09 ATEX0812123x
2. Ambient range (-40°C ≤ Tamb ≤ 75°C)
3. Certification string (Ex nC nL IIC T4)
4. Standards covered ( EN60079-0:2006, EN60079-15:2005)
5. The conditions of safe usage:
y The Ethernet Communication Devices are to be mounted in an IP54
enclosure and used in an area of not more than pollution degree 2 as
defined by IEC60664-1. A 4mm2 conductor must be used when
connection to the external grounding screw is utilized. Conductors
suitable for use in an ambient temperature of 93°C must be used for the
Power Supply Terminal.